Batch Processing Options Window
In Batch Processing Options window you may configure various timeouts used by
Batch Processing Application as well as
specify its output folder:
- Before Printing Timeout - maximum time in seconds Print2Flash
waits for the application (such as MS Word or Adobe Reader) to start
document printing. If this time expires, Print2Flash stops conversion,
returns an error and proceeds to the next document. Zero (0) value means
this timeout is not monitored;
- Printing Timeout - maximum time in seconds Print2Flash waits for
the application to print the document. If this time expires, Print2Flash
cancels the print job, returns an error and proceeds to the next document.
Zero (0) value means this timeout is not monitored;
- Activity Timeout - maximum time in seconds Print2Flash waits for
the application to invoke the next Print2Flash Printer driver function while
printing. This option may be useful for detection of printing application
hang-ups. If an application does not show activity within this timeout (i.e.
does not call the next driver function), Print2Flash returns an error and
proceeds to the next document. Zero (0) value means this timeout is not
monitored;
- After Printing Timeout - maximum time in seconds Print2Flash
waits for the application to exit after document printing is completed. If
this time expires, Print2Flash proceeds to the next document. Zero (0) value
means this timeout is not monitored;
- Output Folder - specifies the folder to which output Flash and
HTML documents are written.